Sign In | Join Free | My lightneasy.org
China Tengen International Industrial Limited logo
Tengen International Industrial Limited
Tengen International Industrial Limited
Active Member

4 Years

Home > Variable Frequency Inverter >

220V 380V TVFS9 series Variable Frequency Inverter good performance

220V 380V TVFS9 series Variable Frequency Inverter good performance

  • 1
  • 2

Brand Name : Tengen

Model Number : TVFS9

Place of Origin : Zhejiang, China (Mainland)

MOQ : 1 Piece/Pieces

Price : US $150-600 / Piece

Payment Terms : T/T, L/C, Western Union

Supply Ability : 5000 Pieces per Month

Delivery Time : 8-15 Work Days

Packaging Details : Each product has independent package

Model : TVFS9

Output Frequency : 0-400HZ

Size : 585*352*274.2

Frequency range : 0Hz~400Hz

Input Voltage : 220V/380V

Control Mode : Speed Sensorless Vector Control

Frequency of Starting : 0.0Hz~10.00Hz

Contact Now

220V 380V TVFS9 series variable frequency Inverter good performance

TVFS9 series inverter is a type of sensorless current vector inverter independently developed by Tengen Group Co. Ltd. On premise of enhancing stability, more advanced functions are available, like motor constant self-identification, analog current input, switch value input, flexible frequency setting method , online switch of multiple frequency setting methods, online constant modification, pulse frequency setting, power failure constant memory, transverse operation with fixed amplitude and variable amplitude, RS485 communication, etc. TVFS9 provides manufacturers and ender users with highly integrated all-in-one solution. It is greatly helpful for cutting down the purchasing cost and company operation cost, and improving the system’s reliability.
Usage precautions.
When using TVFS9 series Inverter, please pay attention to below points:
1,Constant Torque Operate in low speed
2,confirmation of motor’s insulation
3,Negative Torque Load
4,mechanical resonance point of load device
5,Capacitor or voltage-sensitive parts to improve power factor
6,To operate with frequency above 50Hz
7,Motor electronic heat protection value
8,Altitude and derating usage
Safety Precautions
1.Never install an Inverter that is damaged or missing components
2. Always hold the case when carrying the Inverter
3. Attach the Inverter to a metal or other noncombustible material.
4 Install a cooling fan or other cooling device when installing more than one Inverter in the same enclosure so that the temperature of the air entering the Inverter is below 40 degree.
TVFS9 4 015
Inverter Series
Voltage Class
No.
220V
2
380V
4
NO.
Adaptation Motor
0015
1.5KW
0075
7.5KW
0110
11KW
0185
18.5KW
1100
110KW
Remarks:TVFS9-DC.
Stands for DC Buss share model
Product Spec.
Item
Standard Spec.
Input
Rated Voltage,Frequency
Single-phase220V,Triphase220V,Triphase 380V;50Hz/60Hz
Alternation allowance
Voltage:-20% ~ +20% Voltage out of balance rate:<3% Frequency:±5%
Output
Rated voltage
0~200V/0~380V
Frequency range
0Hz~400Hz
Overload Capacity
M Type: 150% 1MIN,180% 1second,200% instant protection;
FP Type:120% 1MIN,150% 1second,180% instant protection
Major control function
Modulation Method
Optimized SVPWM
Control Mode
Speed Sensorless Vector Control
Frequency Accuracy
Digital Setting:highest Frequency×±0. 01%;
Simulation Setting:highest Frequency×±0.2%
Frequency Resolution
Digital Setting:0.01Hz;Analog Setting:Max. Frequency×0.1%
Frequency of Starting
0.0Hz~10.00Hz
Torque Boost
Auto torque boost,Manual torque boost 1%~30.0%(effective for V/F mode)
V/F Curve
Linear V/F Curve,Square V/F Curve,User Defining V/F curve
Acceleration /Deceleration time
Time Unit Option(Minute/Second), Max. value is 3600(0.1~3600)
DC Braking
Optional at start or stop,Operation Frequency 0~20Hz,Operation time could set 0~30second
Jog
Jog frequency:0.1Hz~50.00Hz,Job Accelerate and Decelerate time:0.1~3600seconds
Built-in PID
Easy to form closed loop control system, and suitable for process control of pressure, flow rate and so on
Multi-stage Operation
To achieve Multi-stage Operation by built-in PLC or control terminal
textile transverse frequency
To achieve transverse operation with fixed amplitude or variable amplitude
Automatic Voltage Regulation
When the grid voltage changes, the constant output of voltage can be ensured by adjusting the PWM output.
Automatic Energy Saving Operation
To automatically optimize V/F curve according to the Load to achieve energy saving operation
Automatic Current Restriction
To automatically restric the current during operation to avoid frequent over current failure trip
Vector Control
Torque Characteristics
The output is 150% of rated torque at 1Hz. Stable speed accuracy is 0.1%
Motor constant self identification
To achieve the best control effect, motor’s constant self identification can be fulfilled at motor’s complete halt.
Operation Function
Running Command Channel
Operation Panel Setting;Operation Terminal Setting;Serial Port Setting;any mode can be switched to the other model
Frequency Setting Channel
Keyboard analog potentiometer setting;Keyboard button setting; Functional Code Setting;Serial port setting;Terminal UP/DOWN Setting;Analog Voltage Setting;Analog current setting;Pulse Setting;Combination Setting
Switch Input Channel
Forwarder/reverse Command; 6 Group Programming switch value input,30 functions can be at most
Simulation Input Channel
2-way analog signal input, 0~20mA and 0~10V are optional
Analog Output Channel
Could select simulation output of 0~10V,0~20mA, could achieve frequency setting, output frequency and other physical quantity output
switch Output channel
3-way programming open circuit collector output; 1 way relay output signal, variable kinds of physical quantity output can be achieved.
Control Pannel
LED Digital Display
It can display setting frequency, input voltage, output current and other constants
External meter Display
It can display output frequency, input current, output voltage and so on.
Protection Function
Over current protection;Over Pressure protection;Low-Voltage Protection; Over Heating Protection;Over-load Protection
Accessory Choosing
Braking Component;remote operator panel;Remote Cable;Keyboard Fitting Seat and so on
Environment
Where used
Indoor,keep away from direct sunshine,no dust,aggressive gas,oil mist,water vapor and so on
Elevation
less than 1000meters(need to derate if beyond 1000meters)
Environment Temp.
-10℃~+40℃
Humidity
Less than 90%RH,non condensing
Vibration
Less than 5.9 meters/second
Storage Temp.
-20℃~+60℃
structure
Protection Class
IP20(under the state of Operation or Keyboard Display)
Cooling Method
Forced air cooling
Installation Method
Wall Mounting,Cabinet Installation
Inverter Series Model Nos.
TVFS9 series Inverter has got two voltage class: 220V & 380V, adaptive motor’s power range: 0.75KW~400KW, model as below
Table 2-1 TVFS9 TVFS9 series Inverter Model Nos.
Voltage Class
Inverter Model NO.
Rated Output Current(A)
Adaptation Motor(KW)
380V triphase
TVFS9-4007
2.3
0.75
TVFS9-4015
3.7
1.5
TVFS9-4022
5.5
2.2
TVFS9-4037
8.5
4.0
TVFS9-4055
13.0
5.5
TVFS9-4075
17.0
7.5
TVFS9-4110

25.0

11
TVFS9-4150
33.0

15

TVFS9-4185
39.0
18.5
TVFS9-4220
45.0
22
TVFS9-4300
60.0
30
TVFS9-4370
75.0
37
TVFS9-4450
91.0
45
TVFS9-4550
112.0
55
TVFS9-4750
150.0
75
TVFS9-4930
176.0
90
TVFS9-41100
210.0
110
TVFS9-41320
260.0
132
TVFS9-41600
310.0
160
TVFS9-41850
340.0
00
185
TVFS9-42000
385.0
200
TVFS9-42200
430.0
220
TVFS9-42500
475.0
245
TVFS9-42800
535.0
280
TVFS9-43150
600
315
TVFS9-43500
645
350
TVFS9-43750
675
375
TVFS9-44000
750
400
220V
Single-phase
TVFS9-2007
5.0
0.75
TVFS9-2015
7.5
1.5
TVFS9-2022
10.0
2.2
Remarks: Inverter with other specification for 220V voltage can be produced according to customer’s requirement.
Keyboard layout
Operating panel and control terminals can control the motor to run, change speed, stop, brake, set the run parameters and external devices. Operating panel is shown as diagram 4-3 and remote-control keyboard is shown as diagram 4-2.
Keyboard function description
here are eight buttons and one keyboard analog POT on the inverter keyboard, they functions are defined as Table4-1.
Item
Function Description
State instructions Help
Hz
The indicator light When the LED display content for frequency indicator light.
A
The indicator light When the LED display content for current
V
The indicator light When the LED display content for voltage
ALM
The indicator light When Current ,voltage limit operation ,Failure Failure
FWD
The indicator light When inverter in a fwd. operation
REV
The indicator light When inverter in a rev. operation
Hz&A
The two bright lights When the LED display content for Speed
Hz&V
The two bright lights When the LED display content for Percen.
A&V
The two bright lights When the LED display content for LindSpe.
Hz&A&V
The three bright lights When the LED display content for Temper.
Key function
RUN
Run key:Enter into run mode under keyboard mode.
REV/JOG
Jog/ Reverse key:Jog or Reverse run is available when pressing this key under keyboard mode.
STOP/RESET
Stop/Reset key:In common run status the inverter will stop according to set mode after this key is pressed if run command channel is set as panel effective mode. The inverter will reset and resume normal stop status after this key is pressed when the inverter is in malfunction status.
PRG
Program key:Enter into or exit Program/Monitor status
SET
Data/store key:Enter into next level menu or store function code when the inerter is in programming status.
Up/down data:Data or function codes increase or decrease
Shift/Monitor key:Choose the digit of the data which is to be set and modified when the inverter is in edition status; switch monitor parameter to be shown when the inverter is in other statuses.
Basic Running Wiring Digram
Fig.3-5 Basic Running Wiring Diagram FIT MODEL :TVFS9-4007~TVFS9-4185
Note:
1. ---AI2 could select voltage or current signal input, switched by JP1 on the control panel.
2. ---A01 could select Output voltage or current signal, switch by the JP1 on the control panel.
3. --- DI6 Terminal can distinguish high speed pulse signal, D03 can generate high speed pulse signal, but they are non-standard function, special description needs to be given when ordering.
Form3-6 Basic Running Wiring Diagram FIT MODELS: TVFS9-4220~TVFS9-44000M
Remarks:
1. --AI2 is used to select voltage or current signal input, switched by the JP1 on the control panel.
2. ---A01 is used to select Output voltage or current signal, switch by the JP1 on the control panel.
3. DI6 Terminal is used to distinguish high speed pulse signal, D03 could generate high speed pulse signal, but they are non-standard function, should make special description during ordering.
2. Main Circuit Wiring
3. (1),Main Circuit Input and Output Terminals shown as form 3-2.
FIT Models
Main Circuit Terminals
Terminal
Name
Function Description
TVFS9-4007~
TVFS9-4037
R,S,T
Three phase current 380V Input Terminal
U,V,W
Three phase output terminal
P+,PB
braking resistor connection terminal
TVFS9-4055~
TVFS9-4075
R,S,T
Three phase current 380V Input Terminal
U,V,W
Three phase output terminal
P+,PB
braking resistor connection terminal
TVFS9-4110~
TVFS9-4185
R,S,T
Three phase current 380V Input Terminal
U,V,W
Three phase output terminal
P+,PB
braking resistor connection terminal
E
ground terminal
TVFS9-4220~
TVFS9-44000

R,S,T
Three phase current 380V Input Terminal
U,V,W
Three phase output terminal
E
ground terminal
Exterior Dimensions
(a):0.4KW~1.5KW SPEC.(MINI Model) (b):0.75KW~4.0KW SPEC(Standard Model)

(c):5.5KW,7.5KW SPEC. (d):11KW~30KW SPEC.

(e):37KW~132KW SPEC. (f):220KW~400KW SPEC.

Product Tags:

variable frequency drive inverter

      

variable speed drive inverter

      
Buy cheap 220V 380V TVFS9 series Variable Frequency Inverter good performance product

220V 380V TVFS9 series Variable Frequency Inverter good performance Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Tengen International Industrial Limited
*Subject:
*Message:
Characters Remaining: (0/3000)